According to : IEC 60601-1 clause9.6.3
Frequency range : 0.5Hz ~ 400Hz.
Measuring range : 60 dB~180 dB.
Sensor sensitivity : 100mV/g
IEC 60601-1- Hand transmitted vibration,Vibration Meter
Technical parameters:
  1. According to IEC 60601-1 clause9.6.3
  2. Channel: 3.
  3. Frequency range: 0.5Hz ~ 400Hz.
  4. Measuring range: 60 dB~180 dB.
  5. Sensor weight: 300g.
  6. Sensor sensitivity: 100mV/g.
  7. Frequency: Line, Wd, Wk, Wm, Wh, VLz, Wb, Wc, We, Wj optional.
  8. Time: F (0.125s), S (1s), stable (8s).
  9. Average score time: 1s to 24h arbitrary setting.
  10. Display refresh rate: instantaneous value 0.5s refresh once.
  11. Display: 3.5-inch, color screen, 320*480 dot matrix, touch screen.
  12. Main configuration: 1 host, 1 whole body vibration acceleration sensor, 1 carrying box, 1 manual

   
TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING
IEC 60601-1:2005 + Am.1:2012
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
| Clause | Measurement/testing | Testing / measuring equipment / material needed | Subcontracting | 
| 4.11 | Power input |   			 Suitable devices for the voltage, current/power and frequency Supply: 1 phase and 3 phase variacs 
  |   			R | 
| 5.3 | Ambient temperature, humidity, atmospheric pressure |   			 Suitable devices for recording ambient temperature, humidity, atmospheric pressure 
  |   			R | 
| 5.7 | Humidity preconditioning treatment |   			 Environmental conditions: Climate chamber controlling temperature and humidity 
  |   			R | 
| 5.9.2 | Accessible parts |   			 Force gauge (30 N), standard test finger (figure 6), straight unjointed test finger, test hook (figure 7) 
  |   			R | 
| 7.1.2 | Legibility of markings |   			 Illuminance meter 
  |   			R | 
| 7.1.3 | Durability of markings |   			 Distilled water, ethanol (96% pure), isopropyl alcohol , timer / stop watch 
  |   			R | 
| 8.4.2 | Accessible parts including applied parts |   			 Oscilloscope, oscilloscope leads, suitable instruments for measuring voltage, current, capacitance, test pin (Figure 8), metal test rod (D = 4 mm, L = 100 mm), force gauge (10 N) 
  |   			R | 
|   			 8.4.3, 8.4.4  |   			Limitations voltage and energy | Suitable oscilloscope recorder /set-up & RCL meter | R | 
| 8.5.5.1 | Defibrillation protection |   			 5 kV test circuit & oscilloscope interface circuit according to Figures 9 & 10, oscilloscope 
  |   			S | 
| 8.5.5.2 | Energy reduction test |   			 The test circuit according to Figure 11, oscilloscope, oscilloscope leads 
  |   			S | 
| 8.6.4 | Impedance and current-carrying capability |   			 Current source (25 A minimum, 50 or 60 Hz, 6 V maximum) 
  |   			R | 
| 8.7 | Leakage currents and patient auxiliary currents |   			 Measuring device according to Figure 12, mains isolation transformers, variacs, voltmeter, millivoltmeter, aluminium foil, diverse circuits (fig. 13-20) 
  |   			R | 
| 8.8.3 | Dielectric strength |   			 High voltage tester, isolating transformer for HV-tests (fig. 28), stop watch / timer 
  |   			R | 
| 8.8.4.1 a) | Ball pressure test |   			 Test equipment according to IEC 60695-10-2 
  |   			R | 
| 8.8.4.2 | Resistance to environmental stress |   			 Apparatus for ageing rubber in oxygen 
  |   			S | 
| 8.9 | Creepage distances and air clearances |   			 Oscilloscope, oscilloscope leads, callipers, micrometer, spacing gauges, force gauge (2 N & 30 N), standard test finger (figure 6) 
  |   			R | 
| 8.9.1.7 | Material groups classification |   			 Test equipment according to IEC 60112 
  |   			S | 
| 8.9.3.4 | Thermal cycling |   			 Heating cabinet 
  |   			R | 
| 8.11.3.5 | Cord anchorage |   			 Force gauge (at least 100 N), torque gauge (at least 0.35 Nm) 
  |   			R | 
| 8.11.3.6 | Cord guards |   			 Weights, angle gauge, radius gauge 
  |   			R | 
| 9.4 | Instability hazards |   			 5° & 10° inclined planes or inclinometer or trigonometric calculation, force gauge (at least 220 N), 20 cm by 20 cm test surface, weights, test threshold (10 mm high and 80 mm wide), 7 cm strap, stop watch / timer 
  |   			R | 
| 9.5.2 | Cathode ray tubes |   			 The relevant tests of IEC 60065, Clause 18. 
  |   			S | 
| 9.6.2.1 | Audible acoustic energy |   			 A-weighted sound pressure level according to ISO 3746, ISO 9614-1 or IEC 61672-1 
  |   			S | 
| 9.6.3 | Hand-transmitted vibration |   			 Measurements are made in accordance with ISO 5349-1. 
  |   			S | 
| 9.7.5 | Pressure vessels |   			 Hydraulic pressure test apparatus 
  |   			S | 
| 9.8 | Hazards associated with support systems |   			 Weights or load cell, 0.1 m2 test surface, stop watch / timer, human body test mass (Figure 33) 
  |   			R | 
| 10.1 | X-radiation |   			 Radiation meter 
  |   			S | 
| 10.3 | Microwave radiation |   			 Radiation meter 
  |   			S | 
| 10.4 | Lasers | Test equipment according to IEC 60825-1 | S | 
| 11.1 | Excessive temperatures |   			 Temperature indicator/recorder suitable for this function and thermocouples, 4 wire resistance unit, test corner, variac 
  |   			R | 
| 11.2 | Fire prevention |   			 Spark ignition test apparatus (Figure 34), oxygen gas analyzer 
  |   			S | 
| 11.3 | Constructional requirements for fire enclosures | FV tests specified in IEC 60695-11-10 | S | 
| 11.6.2 | Overflow |   			 15° inclined plane or inclinometer or trigonometric calculation, stop watch / timer, high voltage tester 
  |   			R | 
| 11.6.3 | Spillage |   			 Flask or graduated cylinder, stop watch / timer 
  |   			R | 
| 11.6.5 | Ingress of water or particulate matter |   			 Classification tests of IEC 60529 
  |   			W | 
| 11.6.6 | Cleaning and disinfection |   			 Dielectric strength and leakage current tests as appropriate 
  |   			R | 
| 11.6.7 | Sterilization |   			 Sterilisation to client specification 
  |   			S | 
| 13 | Hazardous situations and fault conditions |   			 stop watch / timer, voltmeter, ammeter, temperature indicator / recorder suitable for this function and thermocouples, 4 wire resistance unit, cheesecloth 
  |   			R | 
| 15.3 | Mechanical strength |   			 Force gauge (250 N minimum), circular plane surface 30 mm in diameter, 500 g steel ball, 50 mm thick hardwood board (hardwood > 600 kg/m3), 40 mm step, hardwood doorframe (40 mm2), circulating air oven 
  |   			R | 
| 15.4.2 | Temperature and overload control devices |   			 Positive temperature coefficient devices (PTC’s) with IEC 60730-1: 1999, clauses 15, 17, J.15 and J.17 
  |   			S | 
| 15.4.3.4 | Primary Lithium batteries |   			 Performance of the tests identified in IEC 60086-4 
  |   			S | 
| 15.4.3.4 | Secondary Lithium batteries | Performance of the tests identified in IEC 62133 | S | 
| 15.4.6 | Actuating parts of controls |   			 Force gauge (at least 100 N), torque gauge (at least 6 Nm), stop watch / timer 
  |   			R | 
| 15.4.7 | Cord-connected hand-held and foot-operated control devices |   			 Force gauge (minimum1 350 N), 30 mm diameter test tool, stop watch / timer 
  |   			R | 
| 15.4.7.3 | Entry of liquids |   			 Classification tests of IEC 60529 
  |   			W | 
| 15.5.1.1 | Transformers |   			 Winding tester for transformers, temperature indicator/recorder suitable for this function and thermocouples variac, loads 
  |   			R | 
| 15.5.2 | Dielectric strength |   			 5x voltage / 5x frequency dielectric strength test fixture, stop watch / timer 
  |   			R | 
| 16.6 | Leakage currents |   			 As in sub-clause 8.7 
  |   			R | 
| A 10.4 | Light emitting diodes (LEDs) |   			 As specified in IEC 62471 
  |   			S | 
| G | Protection against hazards of ignition of flammable anaesthetic mixtures |   			 4 mm & 12 mm diameter test rods, timer / stop watch, gasket test B-b of IEC 60068-2-2, force gauge (minimum 100 N), gas pressure meter (0 to 400 Pa range), voltmeter, ammeter, ohmmeter, meter for capacitance and inductance, oxygen mixture ( volume percentage 12,2 % ± 0,4 %),test apparatus for flammable mixtures (Figure G.7), 
  |   			S | 
| G.4.3 | Prevention of electrostatic charges |   			 antistatic material testing according to ISO 2882 
  |   			S | 
| L | Insulated winding wires for use without interleaved insulation | Sample is preparation according to IEC 60851-5:1996 & dielectric according to 60601-1; flexibility and adherence test 8 of IEC 60851-3:1996; mandrels of diameters according to Table L.1; heat shock test 9 of IEC 60851-6:1996; 2 mm diameter shot of stainless steel, nickel or nickel plated iron. | S | 
| 
                                             | 
                
                        IEC 60601-1- Hand Transmitted Vibration Meter With 100mV/g Sensor Sensitivity Images |